Functionality The user exit EXIT_SAPLQAPP_001 is called from module QAPP_IP_CREATE_1. This module is run through when you go into the create, change and display transactions for the results recordings. This is independent of
whether the inspection point data screen is called up at a later time. The following data is transferred to the user exit: - I_QALS Inspection lot
- I_QAPO Operation of the order
- I_QAPP Inspection point data that is known at this point in time
Function/Program:- EXIT_SAPLQAPP_001: Customer Exit 1 for Inspection Point Processing
|